Operating Instructions Safety Switch CES-AP-C01-CH
24
Switching distances
Operating distance for center offset m = 0
(only in combination with actuator CES-A-BRN)
Parameter Value Unit
min. typ. max.
Switch-on distance - 27 -
mm
Assured switch-on distance s
ao
1)
20 - -
Switching hysteresis
1)
- 3 -
Assured switch-off distance s
ar
- - 75
1) The values apply for surface installation of the actuator on steel.
Typical operating distance