Operating Instructions Safety Switch CES-AP-C.2-CH
17
Technical data
Note:
If a product data sheet is included with the product, the information on the data
sheet applies in case of discrepancies with the operating instructions.
Technical data for safety switch CES-AP-CR2-CH/
CES-AP-CL2-CH
Parameter Value Unit
min. typ. max.
Housing material Plastic PBT
Dimensions 95 x 30 x 12 mm
Weight 0.04 kg
Ambient temperature at U
B
= 24 V DC
°C
- Plug connector with latching
connection
- 30 - + 65
- With connection cable with M12
plug connector
- Connection cable laid rigidly - 40 - + 65
- Connection cable movable 0 - + 65
Storage temperature - 40 - + 70
Degree of protection IP69K
(IP67 for version with M12 plug connector)
Safety class III
Degree of contamination 3
Installation position Any
Connection Plug connector or connection cable
Operating voltage U
B
(reverse polar-
ity protected, regulated, residual
ripple < 5%)
24 ± 15% (PELV) V DC
For the approval according to
the following applies
Operation only with UL class 2 power supply, or equivalent
measure
Current consumption 30 mA
Switching load according to
DC 24 V, class 2
External fuse
(operating voltage)
0.25 - 1.5 A
Safety outputs OA/OB Semiconductor outputs, p-switching, short circuit-proof
- Output voltage U(OA)/U(OB)
1)
HIGH
U(OA)
U
B
-1.5 - U
B
V DC
HIGH
U(OB)
LOW
U(OA)/U(OB) 0 1
Switching current per safety output 1 - 150 mA
Utilization category according to
EN IEC 60947-5-2
DC-13 24 V 150 mA
Caution: outputs must be protected with a free-wheeling diode in
case of inductive loads.
Off-state current I
r
≤ 0.25 mA
Monitoring output OUT
1)
Semiconductor output p-switching, short circuit-proof
- Output voltage 0.8 x U
B
- U
B
V DC
- Max. load - - 50 mA
Rated insulation voltage U
i
- - 75 V
Rated impulse withstand voltage
U
imp
- - 1.5 kV
Resilience to vibration
In acc. with EN IEC 60947-5-2
Switching frequency - - 1 Hz
Repeat accuracy R ≤ 10 %
EMC protection requirements In acc. with EN IEC 60947-5-3
Reliability values according to EN ISO 13849-1
Category 4
Performance Level PL e
PFH
d
1.8 x 10
-9
/ h
Mission time 20 years
1) Values at a switching current of 50 mA without taking into account the cable lengths.