Operating Instructions Safety Switches CES-AR-C.2-CH
21
Setup
LED indicators
LED Color State Significance
STATE
green
illumi-
nated
Normal operation
flashing
- Teach-in operation or Power Up 
- Actuator in boundary area (V. 1.1.2 or higher
(further signal functions: see status table)
DIA
red
illumi-
nated
- Internal electronics fault
- Fault at the inputs/outputs
Initial setup
1.  Apply operating voltage to the safety switch.
¨ The green LED flashes quickly (approx. 10 Hz). 
A self-test is performed during this time (approx. 8 s). After this, the LED 
flashes cyclically one time and signals that it is in standby state.
2.  Move actuator to the read head (observe distance < S
ao
).
¨ The  green  LED  illuminates  continuou sly  and  i ndicates the  detec tion  of  the 
actuator.
If the green LED is flashing at approx. 2 Hz, the actuator is in the boundary area. 
In this case the safety guard must be re-adjusted such that the actuator is com-
pletely in the read area.
Functional check
After installation and any fault, the safety function must be fully checked. Proceed 
as follows:
Warning!
Danger of fatal injury as a result of faults in installation and functional check.
Ì Before carrying out the functional check, make sure that there are no per-
sons in the danger area.
Ì Observe the valid accident prevention regulations.
1.  Switch on operating voltage.
Ì The safety switch carries out a self-test.  
The green LED STATE flashes for 8 s with 10 Hz. 
The STATE LED then flashes at regular intervals.
2.  Close all safety guards.
Ì The machine must not start automatically.
Ì The green STATE LED illuminates continuously.
3.  Enable operation in the control system.
4.  Open the safety guard.
Ì The machine must switch off and it must not be possible to start it as long as 
the safety guard is open.
Ì The green LED STATE flashes at regular intervals.
Repeat steps 2-4 for each safety guard.