Operating Instructions Evaluation Unit CES-A-V1B-01B-AS1
EUCHNER GmbH + Co. KG Kohlhammerstraße 16 D-70771 Leinfelden-Echterdingen Tel. +49 711 7597-0 Fax +49 711 753316 info@euchner.de www.euchner.de
Figure 2: Dimension drawing CES...AS1 Figure 3: Typical operating distance
Side
lobe
N
-10-15 -5 0
Centre offset m [mm]
Distance s [mm]
OFF
ON
Switch-on
distance S
a0
ON
OFF
Hysteresis
Distance
s
S
a0
Output stage
Switch-off
distance
OFF
Hysteresis
-20 5 201510
5
10
15
20
Side
lobe
N
Actuator
Read head
s
m
With evaluation unit CES-A-V1B-01B-AS1 in conjunction with read
head CES-A-LNA...AS1 or CES-A-LNA-SC and actuator CES-A-BBA
on surface mounting of the read head and the actuator. If installed
flush, the switching distance changes as a function of the installation
depth and the safety guard material.
For a side approach direction for the actuator and read head, a
minimum distance of s = 3 mm must be maintained so that the
operating distance of the side lobes is not entered.
Bottom
of housing
Top of housing
with evaluation
electronics
60
149 2,5
Ø 4,3
4,5
max. 39
28,5
78
112
4,3
4,2
33
39
Fastening screw
Mounting straps
Mounting hooks
Labeling clips
Important:
f We recommend the use of CES-A-LNA-SC read
heads. If other read heads are used, other operat-
ing distances are applicable. Please contact our
support team for more detailed information.
f The CEM and CET guard locking devices do not fea-
ture guard lock monitoring according to EN 1088
and therefore must be used only as guard locking
devices for process protection.
f If the CKS key adapter is used in combination with
this evaluation unit, the LED of the CKS key adapter
cannot be activated.
Table 3: Possible combinations
Evaluation unit Read head
Actuator
CES-A-BBA
071840
CES-A-BCA
088786
CES-A-BMB
077791
CES-A-BQA
098108
CKS-A-BK1-RD
113461
CEM-A-BE05
094805
CEM-A-BH10
095175
CET-A-BWK-50X
096327
CES-A-V1B-01B-AS1
096631
CES-A-LNA-SC
077715
CES-A-LMN-SC
077790
CES-A-LQA-SC
095650
CKS-A-L1B-SC
113130
CEM-A-LE05K-S2
094800
CEM-A-LE05R-S2
095792
CEM-A-LH10K-S3
095170
CEM-A-LH10R-S3
095793
CET1-AX
All items
Key to symbols
Combination possible
Combination possible, guard locking for process protection
Combination possible, guard locking for personal protection
Combination not permissible
Komentáře k této Příručce